SENSOREX傳感器ODO9000產(chǎn)品介紹
SPECIFICATIONS | |
Measurement Principle | Optical measurement via luminescence |
Measurement Ranges | 0.00-20.00 mg/L |
Accuracy | ± 0.1 mg/L |
Response Time | 90% in less than 60 seconds |
Measurement Interval | > 5s |
Membrane Cap | Cross Sensitivity: Organic solvents (acetone, toluene, chloroform, methylene chloride); Chlorine gas No Cross Sensitivity: pH 1-14, H2 S, CO2 , SO2 |
Temperature Compensation | 10K NTC |
Temperature Accuracy | 0.5°C |
Sample Temperature | 0-50°C (32 to 122°F) |
Max Pressure | 5 bar (72.5 PSI) |
Signal Output | Direct MODBUS RS-485 |
Power Supply | 12 Volts (±1Volt) |
Power Consumption | 1 W |
Dimensions | Diameter: 25 mm (0.98 in) x Length 146 mm (5.75 in) |
Weight | 450g (1lb) for sensor + 3m (10ft) cable |
Material | 316 Stainless Steel(ODO8000), Titanium (ODO9000) |
Protection Rating | IP68 |
SENSOREX傳感器介紹
ODO8000 and ODO9000 - Lumin-S Optical Dissolved Oxygen Sensors with Digital Communication
Product Information
The Lumin-S optical dissolved oxygen sensor delivers reliable DO measurements over a long operating life. There are no membranes to replace, no electrolyte solutions to replenish, and no anodes to clean. Maintaining the sensor is as easy as replacing the optical sensing cap once every 1-2 years, and since all calibration data is stored on the cap, there’s no need to calibrate. This dissolved oxygen sensor outputs a Modbus/RS-485 digital signal for easy PLC integration.
Reliable measurements: Optical sensor technology delivers accurate DO monitoring with no drift and no minimum flow
Long operating life with minimal maintenance: No membranes, electrolyte solutions, or anodes – just replace the cap once every 1-2 years
No calibration: All calibration data is stored on the cap for quick and easy startup
Simple system integration: Use Modbus/RS-485 to integrate with a PLC or other control system
ODO8000 和 ODO9000 - 具有數(shù)字通信功能的 Lumin-S 光學(xué)溶解氧傳感器
產(chǎn)品信息
Lumin-S 光學(xué)溶解氧傳感器可在較長(zhǎng)的使用壽命內(nèi)提供可靠的 DO 測(cè)量。 無(wú)需更換膜,無(wú)需補(bǔ)充電解質(zhì)溶液,也無(wú)需清潔陽(yáng)極。 維護(hù)傳感器就像每 1-2 年更換一次光學(xué)傳感帽一樣簡(jiǎn)單,并且由于所有校準(zhǔn)數(shù)據(jù)都存儲(chǔ)在帽上,因此無(wú)需校準(zhǔn)。 該溶解氧傳感器輸出 Modbus/RS-485 數(shù)字信號(hào),以便于 PLC 集成。
可靠的測(cè)量:光學(xué)傳感器技術(shù)可提供準(zhǔn)確的溶解氧監(jiān)測(cè),無(wú)漂移且無(wú)最小流量
使用壽命長(zhǎng),維護(hù)最少:無(wú)需膜、電解質(zhì)溶液或陽(yáng)極 - 只需每 1-2 年更換一次蓋子
無(wú)需校準(zhǔn):所有校準(zhǔn)數(shù)據(jù)都存儲(chǔ)在瓶蓋上,以便快速輕松地啟動(dòng)
簡(jiǎn)單的系統(tǒng)集成:使用Modbus/RS-485與PLC或其他控制系統(tǒng)集成
SENSOREX傳感器常見(jiàn)型號(hào)及訂貨號(hào):
SENSOREX ODO8000
SENSOREX ODO9000
SENSOREX SENSOR NEW + ORIGINAL+ ONE YEAR WARRANTY
愛(ài)澤工業(yè)成立于2010年,定位于向先進(jìn)制造工業(yè)提供高端制造技術(shù)和設(shè)備。代理經(jīng)營(yíng)世界先進(jìn)的電氣自動(dòng)化、機(jī)械與傳動(dòng)、流體控制、儀器儀表、工具等產(chǎn)品。作為電氣,液壓以及氣動(dòng)解決方案的合作伙伴,我們利用我們的全球協(xié)作團(tuán)隊(duì),為客戶提供先進(jìn)解決方案,市場(chǎng)知識(shí)以及相關(guān)增值服務(wù)來(lái)幫助優(yōu)化客戶的工作效率,提高可靠性和安全性,致力于成為工業(yè)產(chǎn)品和解決方案的優(yōu)質(zhì)渠道。
如果有任何關(guān)于SENSOREX傳感器ODO9000的疑問(wèn),請(qǐng)隨時(shí)與我們電聯(lián),(021-3100 6702),我們將盡全力解決您的問(wèn)題。
If you have any question for SENSOREX products, please feel free to dial 0086-21-3100 6702/ send request email to sales@ize-industries.com / browse our website: jjxdch.cn.
SENSOREX傳感器ODO9000介紹