HACH濁度計1720E產(chǎn)品參數(shù)

Specifications


Accuracy:

±2% of reading or ±0.02 NTU (whichever is greater) from 0 - 40 NTU

Accuracy 2:

±5% of reading from 40 - 100 NTU (Defined according to ISO 15839.)

Alarm:

When connected to sc controller: three set-point alarms, each equipped with an SPDT relay with unpowered contacts rated 5A resistive load at 230 Vac

Certifications:

Listed by ETL to UL 61010A-1: Certified by ETL to CSA C22.2 No. 1010.1: CE certified by Hach Company to EN 61010-1

Certifications 2:

CE certified by Hach Company to EN61326 (industrial levels)

Communication:

When connected to sc controller: MODBUS RS232/RS485, PROFIBUS, HART

Compliance Certifications:

Standard Methods 2130B, USEPA 180.1, Hach Method 8195

Mounting:

Turbidimeter body and head assembly: wall and floor stand; sc controller: wall, pole, panel, and floor stand

Operating Humidity:

5 - 95 % non-condensing

Operating Temperature Range:

0 - 40 °C (Double Sensor System)
0 - 50 °C (Single Sensor System)

Output:

Up to five selectable for 0-20 mA or 4-20 mA; output span programmable over any portion of the 0-100 NTU range; built into the sc Controller

Power Requirements (Hz):

50 - 60 Hz

Power Requirements (Voltage):

100 - 230 VAC

Range:

0.001 - 100 Nephelometric Turbidity Units (NTU)

Repeatability:

Better than ± 1.0 % of reading or ±0.002 NTU, whichever is greater (Defined according to ISO 15839.)

Response Time:

Initial response in 1 minute, 15 seconds for a full-scale step change

Sample Flow Rate:

200 - 750 mL/minute (3.1 - 11.9 gal/hour)

Sample Input:

1/4 inch NPT female, 1/4 inch compression fitting (provided)

Sample Output:

1/2 inch NPT female, 1/2 inch hose barb (provided)

Sample Temperature:

0 - 70°C (32 - 158°F)

Ship Wt. (lbs):

1720E Turbidimeter: 5.9 kg (13 lbs.)
 1720E Turbidimeter and sc200 Controller:6.31 kg (13.9 lbs.)

Signal Average Time:

User selectable from 0, 6, 30, 60, 90 seconds

Storage Conditions:

-20 to 60 °C (-4 to 140 °F)

Weight:

1720E Turbidimeter: 5.9 kg

愛澤工業(yè)(ize-industries)并不是本網(wǎng)站所列所有產(chǎn)品的授權(quán)代理商或經(jīng)銷商。 本網(wǎng)站使用的所有產(chǎn)品名稱,商標(biāo),品牌等均屬于各自品牌廠家所有。 本網(wǎng)站在產(chǎn)品或圖片描述中,出現(xiàn)具有這些名稱,商標(biāo),品牌等信息的產(chǎn)品僅用于識別目的,并非旨在表明任何與持有者的從屬及授權(quán)關(guān)系。

HACH濁度計產(chǎn)品介紹

Continuously flowing sample flows through the patented* bubble removal system, which vents entrained air from the sample stream and eliminates the most significant interference in low level turbidity measurement. The 1720E Turbidimeter is not affected by variations in flow and pressure.

 

Simplicity

A simplified two-module design includes the sensor and the controller interface. The controller accepts two turbidity sensors; adding a second 1720E sensor makes a system with two complete turbidimeters. Connections are simple plug & play.

 

Data Collection and Display

The 1720E Turbidimeter uses the sc200 Controller to receive data from up to two sensors. A built-in data logger collects turbidity measurement at user selectable intervals (1-15 minutes), along with calibration and verification points, alarm history, and instrument setup changes for 6 months. Communications using Modbus? RS485, MODBUS? RS232, HART, or Profibus DP.

 

連續(xù)流動的樣品流經(jīng)獲得專利的*氣泡去除系統(tǒng),該系統(tǒng)可排出樣品流中夾帶的空氣,并消除低水平濁度測量中最顯著的干擾。1720E濁度計不受流量和壓力變化的影響。

 

簡單

簡化的雙模塊設(shè)計包括傳感器和控制器接口??刂破鹘邮軆蓚€濁度傳感器;添加第二個 1720E 傳感器使系統(tǒng)具有兩個完整的濁度計。連接是簡單的即插即用。

 

數(shù)據(jù)收集和顯示

1720E濁度計使用sc200控制器從最多兩個傳感器接收數(shù)據(jù)。內(nèi)置數(shù)據(jù)記錄器以用戶可選擇的時間間隔(1-15 分鐘)收集濁度測量值,以及6個月的校準(zhǔn)和驗證點、警報歷史記錄和儀器設(shè)置更改。使用 Modbus? RS485、MODBUS? RS232、HART或 Profibus DP進(jìn)行通信。

 

HACH濁度計其他常見型號:

HACH 1720E

HACH 1720C

HACH 1720D

 

HACH Turbidity meter NEW + ORIGINAL+ ONE YEAR WARRANTY

 

愛澤工業(yè)成立于2010年,定位于向先進(jìn)制造工業(yè)提供高端制造技術(shù)和設(shè)備。代理經(jīng)營世界先進(jìn)的電氣自動化、機(jī)械與傳動、流體控制、儀器儀表、工具等產(chǎn)品。作為電氣,液壓以及氣動解決方案的合作伙伴,我們利用我們的全球協(xié)作團(tuán)隊,為客戶提供先進(jìn)解決方案,市場知識以及相關(guān)增值服務(wù)來幫助優(yōu)化客戶的工作效率,提高可靠性和安全性,致力于成為工業(yè)產(chǎn)品和解決方案的優(yōu)質(zhì)渠道。

 

如果有任何關(guān)于HACH濁度計1720E的疑問,請隨時與我們溝通(021-31006702)。我們將盡全力解決您的問題。

 

If you have any question for HACH products, please feel free to dial 0086-21-3100 6702/ send request email to sales@ize-industries.com / browse our website:jjxdch.cn.


HACH濁度計1720E產(chǎn)品參數(shù)

免責(zé)聲明:本網(wǎng)站的布局,設(shè)計和編輯版權(quán)歸?上海愛澤工業(yè)設(shè)備有限公司(簡稱ize-industries)所有,保留所有相關(guān)權(quán)利。 Ize-industries銷售工業(yè)領(lǐng)域的全新產(chǎn)品,庫存產(chǎn)品,并不斷開發(fā)渠道購買此類產(chǎn)品。 本網(wǎng)站未經(jīng)所有制造商或商標(biāo)授權(quán)或批準(zhǔn)。ize-industries不是所有制造商的授權(quán)經(jīng)銷商,附屬公司或代表處。除非另有明確說明,否則此處出現(xiàn)的指定商標(biāo),品牌名稱和品牌均為其各自所有者的財產(chǎn)。