GASTRON氣體檢測儀GTD-2000EX-NMP技術(shù)參數(shù)
specification | |
Hazardous Area Standards | EN 50014, EN50019, EN50028 |
Code of protection | Ex d IIC T6 (-20 to 60℃) |
IP Rating | IP 66/67 |
Application | Combustible gas detector |
Measuring Range | 0~100 %LEL (0~5% volume of methane) |
Measuring resolution | 1 %LEL |
Over range indication | Continuously display gas concentration up to 110 %LEL. |
Calibration level | User selectable 20 %LEL ~90 %LEL in 1 %LEL increments |
Analogue output during calibration | 3.0mA |
Repeatability, Short term | ±3% LEL over 1 hour |
Repeatability, Long term | ±10% LEL over 3 months |
Accuracy | ±3% LEL/ Full scale |
Response Time | 90% of full scale in less than 20 sec |
Dimension | 136(W) X 166(H) X 110(D) mm |
Weight including Sensor | App. 1.5kg |
Cable inlet | 1/2" or 3/4" PF, NPT (3/4" PF standard) |
Operating temperature range | -20 ~ 60℃ |
Storage temperature range | -20 ~ 60℃ |
Relative humidity range | 5% ~ 99%RH |
Operating pressure range | 90Kpa /110Kpa |
Operating Altitude (max) | 1000 m |
Non operating Altitude (max) | 2000 m |
EMC (electromagnetic compatibility) | Comply with EN50270 |
Supply voltage | 18VDC/31VDC |
Supply voltage ripple & noise max | 1Vpp |
Current consumption (typical /max) | 150mA/250mA@24VDC |
Analog output current range | 0-22.0 mA |
Gas concentration output current range | 4-20 mA |
Analog output current ripple & noise max | 20uApp |
Analog output termination resistance(including total cable resistance) | < 600Ω |
GASTRON氣體檢測儀GTD-2000EX-NMP簡介
GTD-2000Ex型可燃?xì)怏w檢測儀是為防止工廠、儲氣庫、工廠等危險場所發(fā)生瓦斯爆炸事故而研制的。
可燃?xì)怏w檢測儀GTD-2000Ex安裝在危險區(qū)域時,將定期連續(xù)檢測氣體泄漏情況,并用集成液晶顯示器顯示數(shù)據(jù),提供4-20mA標(biāo)準(zhǔn)輸出。此外,對于直流4-20毫安標(biāo)準(zhǔn)輸出,輸出部分距離傳感器部分可達(dá)到2500米。(使用CVVS或CVVSB 1.5sq以上電纜時)
可燃?xì)怏w探測器GTD-2000Ex應(yīng)在海拔1000米以下使用。
Combustible gas detector GTD-2000Ex was developed to prevent unfortunate accidents caused by gas explosions in hazardous places such as plants, gas storages, and factories.
When installed in hazardous area, combustible gas detector GTD-2000Ex will regularly and continuously detect the gas leakage and display the data with integrated LCD and to supply 4-20mA standard output. Moreover, for DC 4-20mA standard output, output part can be located up to 2,500 m from sensor part. (When using Cable CVVS or CVVSB 1.5sq above)
Combustible gas detector GTD-2000Ex should be using below 1000M above the sea level.
GASTRON氣體檢測儀GTD-2000EX-NMP其他常見型號:
GASTRON GTD-2000EX-NMP
GASTRON GTD-1000Tx
GASTRON GTD-1000Ex
GASTRON GTD-3000Tx
GASTRON GTD-3000Ex
GASTRON GIR-3000
GASTRON GSA812EX-G3
GASTRON GSA860EX-G3
GASTRON GSA700EX-G3
GASTRON Combustible gas detector NEW + ORIGINAL+ ONE YEAR WARRANTY
愛澤工業(yè)成立于2010年,定位于向先進(jìn)制造工業(yè)提供高端制造技術(shù)和設(shè)備。代理經(jīng)營世界先進(jìn)的電氣自動化、機(jī)械與傳動、流體控制、儀器儀表、工具等產(chǎn)品。作為電氣,液壓以及氣動解決方案的合作伙伴,我們利用我們的全球協(xié)作團(tuán)隊,為客戶提供先進(jìn)解決方案,市場知識以及相關(guān)增值服務(wù)來幫助優(yōu)化客戶的工作效率,提高可靠性和安全性,致力于成為工業(yè)產(chǎn)品和解決方案的優(yōu)質(zhì)渠道。
如果有任何關(guān)于GASTRON氣體檢測儀GTD-2000EX-NMP的疑問,請隨時與我們溝通(021-31006702)。我們將盡全力解決您的問題。
If you have any question for GASTRON products, please feel free to dial 0086-21-3100 6702/ send request email to sales@ize-industries.com / browse our website: jjxdch.cn.
GASTRON氣體檢測儀GTD-2000EX-NMP產(chǎn)品參數(shù)
納分析儀
熱切換儀丨熱分析儀
諧波分析儀
PH計丨PH(ORP) (REDOX)傳感器丨ORP測定儀
表面/界面性能測定儀
測厚儀
測量計量儀器
尺寸檢測儀
充電板監(jiān)測器
磁導(dǎo)率測試儀
磁通計丨高斯計
電導(dǎo)率分析儀
電工儀器儀表
電化學(xué)分析儀器
噸位監(jiān)測儀
二氧化硅分析儀丨硅表
反射率儀丨反射計丨折光計丨折光率儀
光譜分析儀
光學(xué)儀器
函數(shù)信號發(fā)生器
環(huán)境監(jiān)測儀器
混凝土測定儀
檢漏儀
靜電檢測裝置
雷達(dá)發(fā)生器
粒度丨顆粒丨粉末分析儀器及配件
粒子計數(shù)器丨粒子收集器
流量儀表
露點儀
螺紋檢測儀
濃度檢測儀
其他分析儀配件
氣體分析儀丨氣體檢測儀丨氣體探測儀
氣相色譜儀丨配件
去離子單元
燃燒測定儀丨燃燒分析儀
色譜分析儀
示波器
數(shù)據(jù)記錄儀丨圖形記錄器
水分測定儀丨配件
水質(zhì)分析儀
探針/探針配套
溫度儀表丨測溫儀表
無損檢測丨探傷儀器
物位/液位儀表
顯示儀表
校驗儀表
校驗裝置及儀表
行業(yè)專用儀器
壓力儀表
鹽度分析儀
氧分析儀(純水)
元素分析儀器
質(zhì)譜分析儀
濁度計