一文讀懂防爆,本安和危險(xiǎn)區(qū)域
ATEX涉及2個(gè)歐盟指令。第一個(gè)是ATEX 137工作場(chǎng)所指令,第二個(gè)是ATEX 95設(shè)備指令。
ATEX 137工作場(chǎng)所指令(也稱為99/92 / EC)涉及保護(hù)在爆炸性環(huán)境中可能處于危險(xiǎn)之中的勞動(dòng)所需的最低要求。
ATEX 95設(shè)備指令(也稱為94/9 / EC)涉及在潛在爆炸性環(huán)境中使用設(shè)備和系統(tǒng)。
The term ATEX refers to 2 European Directives. The first being the ATEX 137 Workplace Directive and the second is the ATEX 95 Equipment Directive.
The ATEX 137 Workplace Directive (also known as 99/92/EC) relates to the minimum requirements needed for the protection of the workforce who may be at risk in explosive atmospheres.
The ATEX 95 Equipment Directive (also known as 94/9/EC) relates to the use of equipment and systems in potentially explosive atmospheres.
保護(hù)概念 | ||
區(qū)域 | 風(fēng)險(xiǎn) | 保護(hù)概念 |
0 | 在其中爆炸性氣體/空氣混合物長(zhǎng)時(shí)間連續(xù)存在。 | Exia 或 Exs |
1 | 在正常操作中,可能會(huì)發(fā)生爆炸性氣體/空氣混合物。 | Exd. Exe, Exib, Exp, Exia, Exs |
2 | 在正常操作中不太可能發(fā)生爆炸性氣體/空氣混合物。 | 適于區(qū)0和1,EXN,ExN和EXQ所有概念 |
Protection Concepts | ||
Zone | Hazard | Protection Concepts |
0 | In which an explosive gas/air mixture is continuously present for long periods. | Exia or Exs |
1 | In which an explosive gas/air mixture is likely to occur in normal operation. | Exd. Exe, Exib, Exp, Exia, Exs |
2 | In which an explosive gas/air mixture is not likely to occur in normal operation. | All concepts suitable for Zone 0 & 1, ExN, ExO and Exq |
保護(hù)方式標(biāo)準(zhǔn) | ||
保護(hù)方式 | 英國(guó)允許使用區(qū)域 | 代碼字母IEC,EX ..,CENELEC,EEX |
一般要求 | — | — |
油浸 | 2 | o |
加壓 | 1 or 2 | p |
粉末填充 | 2 | q |
隔爆 | 1 or 2 | d |
增安 | 1 or 2 | e |
本安 | * 0, 1 or 2 | ia or ib |
不易燃 | 2 | n # |
封裝形式 | 1 or 2 | m |
特殊 | 1 or 2 | s |
* ia:區(qū)域0、1、2 / ib:區(qū)域1或2,但不是區(qū)域0 | #n:在英國(guó)本地使用 |
Standards For Methods Of Protection | ||
Method Of Protection | Permitted Zone Of Use In UK | Code Letter IEC, EX.., CENELEC, EEX |
General requirement | — | — |
Oil immersion | 2 | o |
Pressurisation | 1 or 2 | p |
Powder filling | 2 | q |
Flameproof | 1 or 2 | d |
Increased safety | 1 or 2 | e |
Intrinsic safety | * 0, 1 or 2 | ia or ib |
Non-incendive | 2 | n # |
Encapsulation | 1 or 2 | m |
Special | 1 or 2 | s |
* ia: Zone 0, 1, 2 / ib: Zone 1 or 2 but not Zone 0 | # n: used locally in UK |
氣體組別 | |
氣體#組CENELEC EN 5014, IEC | 代表型氣體 |
I * (礦業(yè)) | 甲烷 |
IIA | 丙烷 |
IIB | 乙烯 |
IIC | 氫 |
Gas Grouping | |
Gas # Group CENELEC EN 5014, IEC | Representative Gas |
I * (mining) | Methane |
IIA | Propane |
IIB | Ethylene |
IIC | Hydrogen |
溫度等級(jí) | |
T級(jí)/ IEC 79-7 | 最高表面溫度°C |
T1 | 450°C |
T2 | 300°C |
T3 | 200°C |
T4 | 135°C |
T5 | 100°C |
T6 | 85°C |
Temperature Classification | |
T Class / IEC 79-7 | Max. Surface Temp °C |
T1 | 450°C |
T2 | 300°C |
T3 | 200°C |
T4 | 135°C |
T5 | 100°C |
T6 | 85°C |
認(rèn)證代碼(CENELEC標(biāo)記信息-示例[EEx ia] IIC T4) | ||||||
[ | E | Ex | ia | ] | IIC | T4 |
相關(guān)設(shè)備* | 通過CENELEC標(biāo)準(zhǔn)認(rèn)證 | 防爆保護(hù) | 保護(hù)概念(IS) | 相關(guān)設(shè)備* | 設(shè)備組 | 溫度等級(jí) |
*(位于安全區(qū)域中,可能連接到危險(xiǎn)區(qū)域) |
Certification Code (CENELEC marking information - example [EEx ia] IIC T4) | ||||||
[ | E | Ex | ia | ] | IIC | T4 |
Associated apparatus* | Certified to the CENELEC standard | Explosion protected | Protection concept (IS) | Associated apparatus* | Apparatus group (gas group) | Temperature classification (not Gp I) |
* (located in safe area and may be connected to hazardous area) |
設(shè)備組和類別 | ||
設(shè)備組 | 設(shè)備類別 | 區(qū) |
I | M = 礦業(yè) | — |
礦業(yè) | M 1 | — |
礦坑氣體/或可燃粉塵 | M 2 | — |
II | G = 氣體 | |
其他領(lǐng)域 | 1 G | 0, 1, 2 |
易爆氣體環(huán)境 | 2 G | 1, 2 |
3 G | 2 | |
在認(rèn)證類別編號(hào)中的G之后添加D | D = 灰塵 | |
(即GD)(如果設(shè)備也通過了粉塵類別批準(zhǔn)) | 1 D | 20, 21, 22 |
2 D | 21, 22 | |
3 D | 22 | |
類別說明: |
Device Group & Category | ||
Device Group | Device Category | Zone |
I | M = Mining | — |
Mining | M 1 | — |
Pit Gas &/or Flammable Dusts | M 2 | — |
II | G = Gas | |
Other Areas | 1 G | 0, 1, 2 |
Explosive Atmosphere | 2 G | 1, 2 |
3 G | 2 | |
D is added after G in the certification class number | D = Dust | |
(i.e. GD) if device is dust category approved also | 1 D | 20, 21, 22 |
2 D | 21, 22 | |
3 D | 22 | |
Explanation of the categories: |
閃點(diǎn)
這是液體產(chǎn)生足夠的蒸氣以支持點(diǎn)火的最低溫度。該蒸氣可以通過多種方式被點(diǎn)燃,包括溫度或能量(即火花)。
點(diǎn)火溫度
這是蒸氣被點(diǎn)燃的最低溫度。這定義了溫度等級(jí)。
Flashpoint
This is the lowest temperature at which a liquid generates sufficient vapour to support ignition. This vapour can be ignited in many ways including temperature or energy (i.e. a spark).
Ignition Temperature
This is the lowest temperature at which the vapour will be ignited. This defines the temperature class.
電氣設(shè)備的最高表面溫度分類(CENELEC) | |
溫度等級(jí) | 最高表面溫度 |
T1 | <450oC |
T2 | <300oC |
T3 | <200oC |
T4 | <135oC |
T5 | <100oC |
T6 | <85oC |
Classification of Maximum Surface Temperatures of Electrical Apparatus (CENELEC) | |
Temp. Class | Max. Surface Temp. |
T1 | <450oC |
T2 | <300oC |
T3 | <200oC |
T4 | <135oC |
T5 | <100oC |
T6 | <85oC |
儀器組(能量點(diǎn)火)
所有地面工業(yè)氣體/蒸氣均歸為第二類氣體,第二組分為3個(gè)子組:
IIA –點(diǎn)燃需要高能量。爆炸強(qiáng)度較小。(丙烷)
IIB –點(diǎn)燃所需的能量更少。爆炸更激烈。(乙烯)
IIC –點(diǎn)火所需的能量很少。最強(qiáng)烈的爆炸。(氫)
Apparatus Group (Energy Ignition)
All surface industry gases/vapours are classed as Group II gases. Group II is divided into 3 sub groups:
IIA – High energy is required to ignite. Less intense explosion. (Propane)
IIB – Less energy is required to ignite. More intense explosion. (Ethylene)
IIC – Little energy is required to ignite. Most intense explosion. (Hydrogen)
一些常見易燃材料的特性 | ||||
氣體/蒸氣 | 閃點(diǎn) | 燃?xì)?/strong> | 點(diǎn)火溫度 | 溫度等級(jí) |
丙酮 | 19oC | IIA | 535oC | T1 |
丁烷 | -60oC | IIA | 365oC | T2 |
庚烷 | -4oC | IIA | 215oC | T3 |
乙基甲醚 | 37oC | IIB | 190oC | T4 |
注意:點(diǎn)火能量和點(diǎn)火溫度之間無(wú)關(guān) |
Characteristics Of Some Common Flammable Materials | ||||
Gas/Vapour | Flashpoint | Gas Group | Ignition Temp. | Temp. Class |
Acetone | 19oC | IIA | 535oC | T1 |
Butane | -60oC | IIA | 365oC | T2 |
Heptane | -4oC | IIA | 215oC | T3 |
Ethyl Methyl Ether | 37oC | IIB | 190oC | T4 |
Note: There is no connection between ignition energy and ignition temperature |